27 Nov

Real HCPA-UPS H19-311-ENU Practice Questions

Planning for H19-311-ENU HCPA-UPS-ENU (Huawei Certified Pre-sales Associate-UPS-ENU) exam with real H19-311-ENU practice questions is a great way to complete HCPA-UPS H19-311-ENU exam. Real HCPA-UPS H19-311-ENU Practice Questions have been updated on Nov.16, which ensure your success in HCPA-UPS exam. 

HCDAtest not only offers Real HCPA-UPS H19-311-ENU Practice Questions to help you pass H19-311-ENU exam, but also have H19-311-ENU free demo questions to let you check the high quality of HCPA-UPS H19-311-ENU practice questions.

Begin to Test:

1. The input power factor (full load) of the UPS5000A is (), which can efficiently reduce the pollution to the power grid and save the preceding power distribution investment.

 
 
 

2. Which of the following are the monitoring methods used by the UPS2000-A series (6 kVA to 10 kVA) with an SNMP card? (Multiple Choice)

 
 
 

3. Which of the following types does the UPS5000-A belong to?

 
 
 

4. The output capacity of a single UPS is calculated on actual power when the actual load power is used for UPS configuration.

 
 

5. If the system is configured with 15-minute battery backup duration, the discharge cutoff voltage of a single battery is ().

 
 
 
 

6. The bypass module in the UPS5000-E-200K is the same as that in the UPS5000-E-400K.

 
 

7. Which of the following communication methods does the UPS2000-G series (6 kVA to 20 kVA) support? (Multiple Choice)

 
 
 
 
 

8. The model of the UPS2000-G-6KRTL is ().

 
 
 
 

9. Which of the following products is similar to the modular UPSs of the UPS5000-E series in product features?

 
 
 
 

10. For 80 kW IT loads, configuring an 80 kVA UPS can meet the basic requirements.

 
 

11. The UPS5000-E can realize convenient and simple N+X power supply system only by configuring a ().

 
 
 
 

12. When using a UPS5000-E (50 kVA power module) with the actual load of 160 kW, 1+1 rack redundancy, and single UPS backup solution, each rack uses three battery strings, each battery string consists of 40 batteries, and the main switch box capacity is ().

 
 
 
 

13. The UPS2000-G is designed with high power density, with 2 U height for the 6 kVA and 10 kVA capacity models and 3 U height for the 15 kVA and 20 kVA capacity models.

 
 

14. If the UPS5000-E (50 kVA power module) backs up power without derating, it is unreasonable to configure () 12 V batteries.

 
 
 
 

15. Which of the following is not a configuration option of the 20-kVA UPS2000-G? ()

 
 
 
 

16. Batteries of different discharge currents have different requirements for the cutoff voltage. Typically, the () the discharge current is, the () the cutoff voltage is.

 
 
 

17. The UPS5000-A can obviously reduce harmonic pollution to the power grid. The input current wave form distortion THDi is () at full linear loads.

 
 
 
 

18. The UPS2000-G series (6 kVA to 20 kVA) supports up to () UPSs in parallel, providing excellent scalability.

 
 
 
 

19. The battery voltage of the UPS2000-G is 240 V for the 6-10 kVA capacity models, and is 480 V for the 15 kVA and 20 kVA capacity models.

 
 

20. Which of the following statements are correct about the UPS5000-A smart battery management? (Multiple Choice)

 
 
 
 

21. Which of the following basic project information doesn’t need to be entered manually before configuration quotation? ()

 
 
 
 

22. The UPS2000-G series (6 kVA to 20 kVA) features an industry-leading lightning protection design, with a lightning protection level of () and a surge protection level of (), which avoids 90% of failures caused by lightning strikes and offers reliable protection for the AC input ports on back-end devices.

 
 
 
 

23. The UPS5000-A parallel signal cable does not adopt ring connection, which reduces system reliability because of the possibility of single-point failures.

 
 

24. The Fusion Module500 and Fusion Module800 must have unified network management software configured for remote WebUI monitoring.

 
 

25. Which of the following communication functions does the UPS5000-E support? (Multiple Choice)

 
 
 
 

Question 1 of 25

Real H19-311-ENU questions, accurate answers. If want to get full version of HCPA-UPS H19-311-ENU exam, just come to click the picture.

Any questions about H19-311-ENU practice questions, just contact [email protected].

Leave a Reply


Recent Posts


Tags

H12-211-ENU H12-211-ENU online test H12-211-ENU practice test H12-221-ENU H12-222 H12-222-ENU H12-222-ENU exam dumps H12-223 H12-223-ENU H12-223-ENU questions and answers H12-261-ENU H12-261-ENU exam dumps H12-261-ENU questions and answers H13-511-ENU H13-611-ENU H13-611-ENU exam dumps H13-621-ENU Exam dumps H13-621-ENU exam questions H13-622-ENU h13-623 H13-623-ENU H13-623-ENU exam dumps H19-301-ENU exam dumps H19-307-enu H19-307-ENU exam dumps H19-307-ENU exam questions H19-307-ENU questions and answers H19-308 H31-211-ENU H31-211-ENU exam dumps H31-311-ENU HCDA HCDA (Carrier IP) HCIE-R&S HCNA HCNA-HNTD HCNA-Storage-BSSN HCNA Storage HCNP HCNP-R&S-IENP HCNP-Storage HCNP-Storage-CBDS hcnp R&S HCPA-Server Video Conference